Wang HB, Yang CX, Zhang B, Xia Y, Liu HZ, Liang H
Correspondence: Dr Hua Liang, lhlh2003@126.com
ABSTRACT
INTRODUCTION Sedation or anaesthesia is recommended for all patients undergoing bronchoscopy unless absolute contraindications exist. However, the widely used combination of propofol and opiates for moderate sedation (MS) in bronchoscopy results in a high incidence of hypoxaemia and a relatively high cough score during the procedure. In this study, we evaluated the efficacy and safety of target-controlled infusion (TCI) of propofol and remifentanil, together with the use of high frequency jet ventilation (HFJV), to achieve general anesthesia (GA) in diagnostic fibre-optic bronchoscopy.
METHODS A total of 92 consecutive patients scheduled for flexible bronchoscopy were randomly assigned to receive either MS using TCI-delivered propofol and remifentanil (n = 46), or GA using TCI-delivered propofol and remifentanil with HFJV (n = 46). The following were compared between the MS and GA groups: incidence of hypoxaemia, cough score, haemodynamic parameters, partial pressure of carbon dioxide in arterial blood, duration of bronchoscopy and patient satisfaction score.
RESULTS The average and minimum oxygen saturation values in the MS group were lower than those in the GA group. The MS group showed a higher incidence of hypoxaemia. There was no significant difference in the partial pressure of carbon dioxide between the two groups. Cough score and duration of the bronchoscopy were markedly lower in the GA group, and patient satisfaction score was higher in the GA group.
CONCLUSION GA, achieved via TCI-delivered propofol and remifentanil with HFJV, provides better conditions for diagnostic bronchoscopy – it decreases the occurrence of hypoxaemia, shortens the duration of bronchoscopy and increases patient satisfaction.
Keywords: bronchoscopy, target-controlled infusion, ventilation
Singapore Med J 2013; 54(12): 689-694; http://dx.doi.org/10.11622/smedj.2013243
REFERENCES
1. British Thoracic Society Bronchoscopy Guideline Committee, a subcommittee of the standards of Care Committee of the British Thoracic Society. British Thoracic Society guidelines on diagnostic flexible bronchoscopy. Thorax 2001; 56 Suppl 1:i1-21. http://dx.doi.org/10.1136/thorax.56.suppl_1.i1 | ||||
2. Wahidi MM, Jain P, Jantz M, et al. American College of Chest Physicians consensus statement on the use of topical anesthesia, analgesia, and sedation during flexible bronchoscopy in adult patients. Chest 2011; 140:1342-50. http://dx.doi.org/10.1378/chest.10-3361 | ||||
3. Stoz D, Chhajed P, Leuppi JD, et al. Cough suppression during flexible bronchoscopy using combined sedation with midazolam and hydrocodone: a randomized, double blind, placebo controlled trial. Thorax 2004; 59:773-6. http://dx.doi.org/10.1136/thx.2003.019836 | ||||
4. Schwarz Y, Greif J, Lurie O, Tarrasch R, Weinbroum AA. Dextromethorphan premedication reduce midazolam requirement: objective and subjective parameters in peribronchoscopy. Respiration 2007; 74:314-9. http://dx.doi.org/10.1159/000099334 | ||||
5. Urman RD, Kaye AD. Moderate and deep sedation in clinical practice. Cambridge:Cambridge University Press, 2012. http://dx.doi.org/10.1017/CBO9781139084000 | ||||
6. Stoz D, Kurer G, Meyer A, et al. Propofol versus combined sedation in flexible bronchoscopy: a randomised non-inferiority trial. Eur Respir J 2009; 34:1024-30. http://dx.doi.org/10.1183/09031936.00180808 | ||||
7. Clarkson K, Power CK, Connell F, Pathmakanthan S, Burke CM. A comparative evaluation of propofol and midazolam as sedative agents in fiberoptic bronchoscopy. Chest 1993; 104:1029-31. http://dx.doi.org/10.1378/chest.104.4.1029 | ||||
8. Clark G, Licker M, Yoounossian AB, et al. Titrated sedation with propofol or midazolam for flexible bronchoscopy: a randomised trial. Eur Respir J 2009; 34:1277-83. http://dx.doi.org/10.1183/09031936.00142108 | ||||
9. Schlatter L, Pflimlin E, Fehrke B, et al. Propofol versus propofol plus hydrocodone for flexible bronchoscopy: a randomised study. Eur Respir J 2011; 38:529-37. http://dx.doi.org/10.1183/09031936.00121610 | ||||
10. Matot I, Kramer, MR, Glantz L, Drenger B, Cotey S. Myocardial ischemia in sedated patients undergoing fiberoptic bronchoscopy. Chest 1997; 112:1454 - 8. http://dx.doi.org/10.1378/chest.112.6.1454 | ||||
11. Yildiz P, Ozgul A, Yilmaz V. Changes in oxygen saturation in patients undergoing fiberoptic bronchoscopy. Chest 2002; 121:1007-8. http://dx.doi.org/10.1378/chest.121.3.1007 | ||||
12. Veres J, Slavei K, Errhalt P, Seyr M, Ihra G. The Veres adapter: clinical experience with a new device for jet ventilation via a laryngeal mask airway during flexible bronchoscopy. Anesth Analg 2011; 112:597-600. http://dx.doi.org/10.1213/ANE.0b013e3182080407 | ||||
13. Sarkiss M. Anesthesia for bronchoscopy and interventional pulmonary: from moderate sedation to jet ventilation. Curr Opin Pulm Med 2011; 17:274 - 8. http://dx.doi.org/10.1097/MCP.0b013e3283471227 | ||||
14. Mchugh R, Kumar M, Sprung J, Bourke D. Transtracheal jet ventilation in management of the difficult airway. Anaesth Intensive Care 2007; 35:406-8. | ||||
15. Yoon HI, Kim JH, Lee JH, et al. Comparison of propofol and the combination of propofol and alfentanil during bronchoscopy: a randomized study. Acta Anaesthesiol Scand 2011; 55:104-9. http://dx.doi.org/10.1111/j.1399-6576.2010.02336.x | ||||
16. Hwang J, Jeon Y, Park HP, Lim YJ, Oh YS. Comparison of alfentanil and ketamine in combination with propofol for patient-controlled sedation during fiberoptic bronchoscopy. Acta Anaesthesiol Scand 2005; 49:1334-8. http://dx.doi.org/10.1111/j.1399-6576.2005.00842.x | ||||
17. Mertens MT, Engbers FH, Burm AG, Vuyk J. Predictive performance of computer-controlled infusion of remifentanil during propofol/remifentanil anaesthesia. Br J Aneasth 2003; 90:132-41. http://dx.doi.org/10.1093/bja/aeg046 | ||||
18. Passot S, Servin F, Allary R, et al. Target-controlled versus manuallycontrolled infusion of propofol for direct laryngoscopy and bronchoscopy. Anesth Analg 2002; 94:1212-6. http://dx.doi.org/10.1097/00000539-200205000-00030 | ||||
19. Iwakiri H, Nishihara N, Nagata O, et al. Individual effect-site concentration of propofol are similar at loss of consciousness and at awakening. Anesth Analg 2005; 100:107-10. http://dx.doi.org/10.1213/01.ANE.0000139358.15909.EA | ||||
20. Egan TD. Remifentanil pharmacokinetics and pharmacodynamics. A preliminary appraisal. Clin Pharmacokinet 1995; 29:80-94. http://dx.doi.org/10.2165/00003088-199529020-00003 | ||||
21. Sivarajan M, Stoler E, Kil HK, Bishop MJ. Jet ventilation using fiberoptic bronchoscopes. Anesth Analg 1995; 80:384-7. | ||||
22. Hautmann H, Gamarra F, Henke M, Diehm S, Huber RM. High frequency jet ventilation in interventional fiberoptic brochoscopy. Anesth Analg 2000; 90:1436-40. http://dx.doi.org/10.1097/00000539-200006000-00034 | ||||
23. Cook TM, Alexander R. Major complications during anaesthesia for elective larygeal surgery in the UK: a national survey of the use of high-pressure source ventilation. Br J Anaesth 2008; 101:266-72. http://dx.doi.org/10.1093/bja/aen139 |